SPECIFICATIONS
Input:
AC input: universal input 100VAC to 240VAC, auto selectable 50Hz to 60Hz
Maximum inrush current: 40A for 110VAC cold start; 20A for 220VAC cold start
Output: output 1, output 2, output 3, output 4, output 5
Voltage: +5, +12, -5, -12, 3.3VDC
Maximum load: 30, 12, 0.5, 0.8, 16A
Minimum load: 8, 4, 0.1, 0.1, 0.3A
(output 1 + output 5: 150W)
Ripple: 50, 120, 50, 120, 40mV
Ripple/noise: 100, 150, 100, 240, 40mV
Line regulation: +/-1%
Load regulation: +/-5%, +/-5%, +/-10%, +/-10%, +/-5%
Cross regulation: +/-5%, +/-5%, +/-10%, +/-10%, +/-5%
Remote on/off control: +5V SB DC output 1.5A (peak 2A)
When PS-on is pulled to TTL low, the DC output is to be enabled
When PS-off is pulled to TTL high, the DC output is to be disabled
Overall performance:
Total output power: 400W continuous maximum
Efficiency: minimum 65% at full load
Hold-up time: 16ms at maximum load and normal input voltage
Power good: TTL compatible signal out with 100ms to 500ms
Description:
Short-circuit protection: all output equipped with short-circuit protection
Overpower protection: peak power is protected between 130% and 160% of
continuous rated power
Hot-swappable and power sharing
MTBF: 80K hours at 25 degrees Celsius.
Environment conditions:
Operating temperature: 0 to 50 degrees Celsius
Cooling: by forced air
Storage temperature: -20 to 70 degrees Celsius
Humidity: 5% to 90%, non-condensing
Safety/Quality Approval
Details:
UL CUL TUV CB NEMKO
EN-55022 CISPER22 ClassB, CE Make, EN-61000-3-2 Harmonics, EN-61000-3-3, FCC
part15 ClassB
ISO9001