Rackmount
Mart Internal Part # : PS1003
SPECIFICATION
Input:
AC input: 96 to 132VAC or 198 to 264VAC, user(or Auto) selectable 50 to 60Hz
Maximum inrush current: 40A for 110VAC cold start; 20A for 220VAC cold start
Output: Output 1 / Output 2 / Output 3 / Output 4 / Output 5
Voltage: +5, / +12 / -5 / -12 / 3.3VDC
Maximum load: 25 / 10 / 0.5 / 0.8 / 14A
Minimum load: 6 / 3 / 0.1 / 0.1 / 0.3A
(output 1 + output 5: 125W)
Ripple: 50 / 120 / 50 / 120 / 40mV
Ripple/noise: 100 / 150 / 100 / 240 / 40mV
Line regulation: +/-1%
Load regulation: +/-5% / +/-5% / +/-10% / +/-10% / +/-5%
Cross regulation: +/-5% / +/-5% / +/-10% / +/-10% / +/-5%
Remote on/off control: +5V SB DC output 750mA (peak 1.5A)
When PS-on is pulled to TTL low, the DC output is to be enabled
When PS-off is pulled to TTL high, the DC output is to be disabled
Overall performance:
Total output power: 350W continuous maximum
Efficiency: minimum 65% at full load
Hold-up time: 16ms at maximum load and normal input voltage
Power good: TTL compatible signal out with 100ms to 500ms
Features:
Short circuit protection: all output equipped with short circuit protection
Overpower protection: peak power is protected between 130% to 160% of continuous
rated power
Environment conditions:
Operating temperature: 0 to 50 degrees Celsius
Cooling: by forced air
Storage temperature: -20 to 70 degrees Celsius
Humidity: 5 to 90%, non-condensing
Reliability:
Mean time between failures: 50K hours at 25 degrees Celsius.
Safety/Quality Approval Details:
UL CUL TUV CB NEMKO DEMKO SEMKO FIMKO
EN-55022 CISPER22 ClaseB, CE Make. EN-61000-3-2 Harmanics,EN-61000-3-3, FCC Part
15, ClassB
ISO9001